Staff Protection & Control Electrical Engineer - T&D in Castleford, Yorkshire
Staff Protection & Control Electrical Engineer - T&D

Staff Protection & Control Electrical Engineer - T&D in Castleford, Yorkshire

Castleford +1 Full-Time 36000 - 60000 £ / year (est.) Home office (partial)
VALLUM ASSOCIATES LIMITED

At a Glance

  • Tasks: Design and integrate protection schemes for power distribution networks up to 132kV.
  • Company: Join Northern PowerGrid, a leader in energy solutions with a focus on innovation.
  • Benefits: Enjoy flexible working, competitive salary, and opportunities for professional growth.
  • Why this job: Make a real impact on the future of energy while working with cutting-edge technology.
  • Qualifications: Experience in protection & control design and strong CAD skills required.
  • Other info: Collaborative environment with opportunities to mentor junior engineers.

The predicted salary is between 36000 - 60000 £ per year.

Location: Northern PowerGrid Offices (Castleford, Hull, Sheffield, York, Stockton, Penshaw, Shiremoor) 4-6 months initially in office 3-5x per week, then flexible working.

Type: Permanent

Overview: Protection Applications Design Engineer responsible for designing and integrating protection schemes across power distribution networks from 11kV to 132kV. The role supports network upgrades, asset replacement, reinforcement, smart grid initiatives, and customer connections while ensuring compliance with national protection standards.

Key Responsibilities:

  • Design protection schemes for feeders, transformers and busbars across 11kV, 20kV, 33kV, 66kV and 132kV networks.
  • Produce protection logic diagrams, tripping schemes and connection drawings using MicroStation V8i or AutoCAD.
  • Develop relay logic, relay settings files and communication protocols (IEC61850, DNP3).
  • Specify current and voltage transformers, relay panels, multicore schedules and termination equipment.
  • Integrate new protection schemes with existing control, protection and SCADA systems.
  • Review protection designs from Independent Connection Providers (ICPs).
  • Support Factory Acceptance Testing (FAT), witness testing, and commissioning activities.
  • Liaise with customers, internal teams and external stakeholders.
  • Deliver designs in line with project timelines, cost and quality requirements.
  • Maintain project documentation, reports and asset data systems.

Requirements:

  • Experience in protection & control design within power distribution networks.
  • Knowledge of National Protection Standards (ENATS, TPS, BEBS, Elexon metering standards).
  • Strong experience with CAD tools (MicroStation V8i and/or AutoCAD).
  • Experience producing relay settings, protection logic and communications files.
  • Ability to work on substation protection systems up to 132kV.
  • Capability to obtain operational substation access authorisations.
  • Strong communication and collaboration skills.

Additional:

  • Involvement in asset replacement, network reinforcement, smart grid upgrades, diversions and new connections.
  • May provide guidance and support to junior engineers within the protection design team.

Locations

Castleford Yorkshire

Staff Protection & Control Electrical Engineer - T&D in Castleford, Yorkshire employer: VALLUM ASSOCIATES LIMITED

At Northern PowerGrid, we pride ourselves on being an excellent employer, offering a dynamic work environment that fosters innovation and collaboration. Our commitment to employee growth is evident through ongoing training opportunities and a supportive culture that values work-life balance, especially with our flexible working arrangements after the initial in-office period. Join us in shaping the future of power distribution while enjoying the benefits of working in a company that prioritises your professional development and well-being.
VALLUM ASSOCIATES LIMITED

Contact Detail:

VALLUM ASSOCIATES LIMITED Recruiting Team

StudySmarter Expert Advice 🤫

We think this is how you could land Staff Protection & Control Electrical Engineer - T&D in Castleford, Yorkshire

✨Tip Number 1

Network like a pro! Get out there and connect with folks in the industry. Attend events, join online forums, or even hit up LinkedIn. The more people you know, the better your chances of landing that Staff Protection & Control Electrical Engineer gig.

✨Tip Number 2

Show off your skills! When you get the chance to chat with potential employers, make sure to highlight your experience with CAD tools and protection design. Bring examples of your work if you can – it’s a great way to demonstrate your expertise in designing protection schemes.

✨Tip Number 3

Be ready for technical questions! Brush up on national protection standards and be prepared to discuss how you've applied them in past projects. This will show that you’re not just a theory whiz but someone who can deliver results in real-world scenarios.

✨Tip Number 4

Don’t forget to apply through our website! We’ve got loads of opportunities waiting for you, and applying directly can give you an edge. Plus, it shows you’re genuinely interested in joining our team at Northern PowerGrid.

We think you need these skills to ace Staff Protection & Control Electrical Engineer - T&D in Castleford, Yorkshire

Protection Scheme Design
MicroStation V8i
AutoCAD
Relay Logic Development
IEC61850
DNP3
Current and Voltage Transformer Specification
SCADA Integration
Factory Acceptance Testing (FAT)
Project Documentation Management
National Protection Standards Knowledge
Communication Skills
Collaboration Skills
Substation Access Authorisation

Some tips for your application 🫡

Tailor Your CV: Make sure your CV is tailored to the role of Staff Protection & Control Electrical Engineer. Highlight your experience with protection schemes and CAD tools like MicroStation V8i or AutoCAD, as these are key for us.

Showcase Relevant Experience: When writing your application, emphasise your experience in power distribution networks and any projects you've worked on that align with our needs. We love seeing how you’ve tackled similar challenges!

Be Clear and Concise: Keep your application clear and to the point. Use bullet points where possible to make it easy for us to see your skills and experiences at a glance. We appreciate straightforward communication!

Apply Through Our Website: Don’t forget to apply through our website! It’s the best way for us to receive your application and ensures you’re considered for the role. Plus, it’s super easy to do!

How to prepare for a job interview at VALLUM ASSOCIATES LIMITED

✨Know Your Protection Schemes

Make sure you brush up on your knowledge of protection schemes for feeders, transformers, and busbars. Be ready to discuss how you've designed or integrated these in the past, especially within the 11kV to 132kV range.

✨Familiarise Yourself with CAD Tools

Since you'll be using MicroStation V8i or AutoCAD, it’s crucial to demonstrate your proficiency with these tools. Bring examples of your work or be prepared to talk through your design process using these applications.

✨Understand National Protection Standards

Get a solid grasp of the relevant national protection standards like ENATS and TPS. You might be asked how these standards influence your design decisions, so having specific examples will help you stand out.

✨Showcase Your Communication Skills

This role involves liaising with various stakeholders, so highlight your communication and collaboration skills. Prepare examples of how you've successfully worked with teams or clients to deliver projects on time and within budget.

Staff Protection & Control Electrical Engineer - T&D in Castleford, Yorkshire
VALLUM ASSOCIATES LIMITED
Location: Castleford

Land your dream job quicker with Premium

You’re marked as a top applicant with our partner companies
Individual CV and cover letter feedback including tailoring to specific job roles
Be among the first applications for new jobs with our AI application
1:1 support and career advice from our career coaches
Go Premium

Money-back if you don't land a job in 6-months

>